FFP1S Disposable Face Respirator with Ear Loops

SKU: RF01

Key Features 

  • Multi-layer protection filters contaminants like dust, particulate matter, viruses, bacteria and other micro-organisms
  • Made of non-woven highly breathable Polypropylene material
  • Ultra-soft fabric for superior comfort over prolonged usage
  • Electrostatically charged filter for enhanced filtering efficiency
  • Water repellent outer layer ensuring that the mask does not soak when in contact with a few drops of water
  • Sweat absorbent innermost layer for utmost comfort during prolonged usage

Color

Certification:

ISI 9473:2002 CM/L-8300137209

  • ISI
  • CDSCO

Share:

Description

This face respirator is designed to filter air contaminants, viruses, bacterial micro-organisms, dust, pollen, and smoke. Allows the user to breathe easy and germ-free. RF01 is an ideal choice for use up to 12 hours (cumulative) in varied industries. This face mask is most suited for different applications in daily activities.

Warranty: 1 year from the date of invoice against any manufacturing defects.

Ideal for use

Painting

Construction

Maintenance

Agriculture

Pharmaceuticals

Drilling

Mining and Quarrying

Petrochemical

Textile

Wood Industries

Download Specifications

Performance Requirements Tested as Per Various Clauses of IS 9473:2002

Vital TestRequirement as per StandardKARAM Respirator
Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002)Requirement as per standard- 80%Exceeds 90%
Breathing Resistance 
(Clause 5.11 of IS 9473:2002)
  • Inhalation Flow- 30 l/min: Should be less than 0.6 mbar
  • Inhalation Flow- 95 l/min: Should be less than 2.1 mbar
  • Exhalation Flow- 160 l/min: Should be less than 3.0 mbar
  • 0.4 mbar
  • 1.7 mbar
  • 2.4 mbar
Total Inward Leakage (Clause 5.4.1 of IS 9473:2002)
  • The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22%
  • The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%
  • 3.36%
  • 9.36%
CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002)Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)< 0.5%
Flammability (Clause 5.6 of IS 9473:2002)The face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameKARAM Respirator does not continue to burn after removal of flame
Bacterial Filtering EfficiencyBacterial filtering efficiency should be >90%> 90%